何成栋,万晓霞,黄新国,陈华培,欧立国,杨瑞平,赵德方.照明与观察几何条件对镀铝纸颜色测量的影响[J].包装工程,2016,37(15):7-11. HE Cheng-dong,WAN Xiao-xia,HUANG Xin-guo,CHEN Hua-pei,OU Li-guo,YANG Rui-ping,ZHAO De-fang.The Influence of Illuminant/Geometric Observation Conditions on Color Measurement of Silver-foiled Paper[J].Packaging Engineering,2016,37(15):7-11. |
照明与观察几何条件对镀铝纸颜色测量的影响 |
The Influence of Illuminant/Geometric Observation Conditions on Color Measurement of Silver-foiled Paper |
投稿时间:2016-05-11 修订日期:2016-08-10 |
DOI: |
中文关键词: 照明/观察 镀铝纸 颜色测量 |
英文关键词: illuminant/observation silver-foiled paper color measurement |
基金项目:国家自然科学基金(61275172);安徽省博士后研究人员科研活动经费(2015B060) |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 分析不同照明/观察条件下镀铝纸的色度与光谱值,从而优化不同几何条件在镀铝纸颜色测量中的应用。方法 使用45°/0°,SCE,SCI等3种测量条件获取不同镀铝纸的颜色信息,并针对镀铝纸配色和镀铝纸颜色心理属性一致性对其进行对比分析。结果 45°/0°和SCE条件下的测量数据不符合镀铝纸配色要求;同一样张测得反射率、亮度与色度值大小规律为:SCI>SCE>45°/0°,不同样张在SCE条件下测得的亮度差(△L*)、色度差(△a*,△b*)以及色差(△E)均介于SCI与45°/0°之间,这是由于SCE测量颜色成分中包含了部分镜面反射光。结论 45°/0°和SCE不可作为镀铝纸配色中颜色测量条件,45°/0°较SCE更适合作为镀铝纸表观色测量条件,更符合颜色视觉评价,不同镀铝纸在SCI条件下测量数据差与在45°/0°条件下测量数据差同时较小时,说明两者一致性好。 |
英文摘要: |
In order to analyze the chroma and spectra of silver-foiled paper under different Illuminant/geometric observation conditions and further to optimize the application of different geometric conditions in color measurement of silver-foiled paper, color data on silver-foil paper were obtained under three geometric conditions: 45°/0°, SCI and SCE, and then the data were analyzed in computer color matching and the consistency of color psychometric attributes on silver-foiled paper. The spectral reflectance data of silver foil paper under 45°/0° and SCE did not meet the requirement of computer color matching. The descent order of the reflectance, lightness and chroma of the same sheet of silver-foiled paper was: SCI>SCE>45°/0°. The value of △L*, △a*, △b* and △E under SCE was between that under SCI and 45°/0°, resulting from the remnant specular light in the measured light. In conclusion, 45°/0° and SCE is infeasible as the measurement condition of silver foil paper in computer color matching. 45°/0° is a better measuring geometry and matches well with the visual assessment for the silver-foiled paper compared to SCE. The consistency of different silver-foiled papers is better when the D-value of lightness and chroma is smaller respectively under 45°/0° and SCI. |
查看全文
查看/发表评论 下载PDF阅读器 |