王杰,尚俊琦,石娟,孙鹏伟,李欢欢,范文莹.采用高效液相色谱法测定PET瓶装饮用水中双酚A及其迁移量[J].包装工程,2019,40(23):70-74. WANG Jie,SHANG Jun-qi,SHI Juan,SUN Peng-wei,LI Huan-huan,FAN Wen-ying.Determination of Bisphenol A and Its Migration in PET Bottled Drinking Water by High Performance Liquid Chromatography[J].Packaging Engineering,2019,40(23):70-74. |
采用高效液相色谱法测定PET瓶装饮用水中双酚A及其迁移量 |
Determination of Bisphenol A and Its Migration in PET Bottled Drinking Water by High Performance Liquid Chromatography |
投稿时间:2019-06-17 修订日期:2019-12-10 |
DOI:10.19554/j.cnki.1001-3563.2019.23.011 |
中文关键词: 高效液相色谱法 饮用水 塑料包装 双酚A 迁移量 |
英文关键词: high performance liquid chromatography drinking water plastic packaging bisphenol A migration |
基金项目:湖北省自然科学基金青年项目(2018CFB316);湖北省教育厅中青年人才项目(Q20182602);湖北省高等学校实验室研究项目(HBSY2018-33);湖北文理学院科研基金项目(2017kypy006,2020170329,xk2018007) |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 建立基于高效液相色谱技术的双酚A分析方法,用于快速准确检测襄阳市售5种PET瓶装饮用水塑料包装中的双酚A含量及其在饮用水中的迁移量。方法 样品经前处理后,采用高效液相色谱-紫外检测器方法分离检测,选择ODS-C18色谱柱(4.6 mm×150.0 mm,5 μm),流动相为甲醇-乙酸铵溶液(体积比为50∶50),柱温为30 ℃,流速为1 mL/min,检测波长为280 nm。结果 双酚A的检出限为0.004 μg/mL,在0.02 μg/mL质量浓度条件下的相对标准偏差为4.32%,在线性浓度为0.01~200 μg/mL内的检测信号与双酚A浓度具有良好的线性相关性(r2>0.9999),方法分析性能满足国标限量要求。襄阳市售主要品牌PET瓶装饮用水包装中虽均含有一定量的双酚A,但饮用水中未检出双酚A。PET包装中双酚A在0.4,4,40 μg/g等3个加标水平的回收率为70.30%~113.00%,饮用水中双酚A在0.1,1,10 μg/g等3个加标水平的回收率为90.00%~119.00%,加标回收结果良好。结论 此方法简便、准确、高效,适用于PET瓶装饮用水包装中双酚A含量及迁移量的分析。 |
英文摘要: |
The work aims to establish a bisphenol A analysis method based on the high performance liquid chroma-tography to rapidly and accurately determine the bisphenol A content and its migration in 5 kinds of plastic packaging for PET bottled drinking water sold in Xiangyang. The pretreated sample was detected by high performance liquid chroma-tography-ultraviolet detection (HPLC-UV) with a column of ODS-C18 (4.6 mm×150.0 mm, 5 μm) at 30 ℃. The mobile phase was methanol-ammonium acetate (V∶V, 50∶50), and the flow rate was 1 mL/min. The detection wavelength was 280 nm. The limit of detection (LOD) of bisphenol A was 0.004 μg/mL, and the relative standard deviation (RSD) was 4.32% at the concentration of 0.02 μg/mL. When the linear concentration was within 0.01~200 μg/mL, the detection signal had a good linear correlation (r2>0.9999) with bisphenol A concentration. The analysis capability of the method met the limited demand of national standard. Certain amount of Bisphenol A was found in the packaging of PET bottled drinking water of major brands sold in Xiangyang, while no bisphenol A was detected in drinking water. The recoveries of bisphenol A in PET packaging at the spiked concentration of 0.4, 4 and 40 μg/g were in the range of 70.30%~113.00%, and the recoveries of bisphenol A drinking water at the spiked concentration of 0.1, 1 and 10 μg/g were 90.00%~119.00%. The proposed method is simple, accurate and efficient, which is suitable for the analysis of bisphenol A content and its migration in the packaging of PET bottled drinking water. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |