陈蚕蚕,阿文伟,张敏,董犇,林勤保,李丹,钟怀宁.GC法测定食品接触用再生PVC中氯乙烯类化合物的迁移量[J].包装工程,2023,44(19):9-14. CHEN Can-can,A Wen-wei,ZHANG Min,DONG Ben,LIN Qin-bao,LI Dan,ZHONG Huai-ning.Determination of Migration of Vinyl Chloride Compounds in Food Contact Recycled Polyvinyl Chloride Materials by Gas Chromatography[J].Packaging Engineering,2023,44(19):9-14. |
GC法测定食品接触用再生PVC中氯乙烯类化合物的迁移量 |
Determination of Migration of Vinyl Chloride Compounds in Food Contact Recycled Polyvinyl Chloride Materials by Gas Chromatography |
投稿时间:2023-08-30 |
DOI:10.19554/j.cnki.1001-3563.2023.19.002 |
中文关键词: 再生聚氯乙烯 氯乙烯 1,1-二氯乙烯 1,1-二氯乙烷 气相色谱 |
英文关键词: recycled polyvinyl chloride vinyl chloride vinylidene chloride 1,1-Dichloroethane gas chromatography |
基金项目:国家重点研发计划项目(2022YFF0607202);国家自然科学基金青年基金项目(42207550) |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 有效考察食品接触用再生聚氯乙烯类材料中氯乙烯、1,1-二氯乙烯和1,1-二氯乙烷的迁移风险。方法 建立测定食品接触用再生聚氯乙烯类材料中氯乙烯、1,1-二氯乙烯和1,1-二氯乙烷在水、酸性、含乙醇、橄榄油和化学替代溶剂中迁移量的气相色谱法。采用DB-624(60 m×250 μm×1.4 μm)毛细管柱对迁移实验后的3种物质进行组分分离,用电子捕获检测器(ECD)进行检测。结果 氯乙烯、1,1-二氯乙烯和1,1-二氯乙烷的色谱分离效果较好,在0.005~0.05 mg/kg内线性关系良好,检出限为0.001 mg/kg,定量限为0.005 mg/kg。当添加量为0.005、0.01和0.02 mg/kg时,3种物质的加标回收率为94.8%~108%,相对标准偏差(n=6)为0.0%~9.0%,均低于10%。结论 该方法具有较好的精密度和准确度,可用于食品接触用再生聚氯乙烯类材料中氯乙烯、1,1-二氯乙烯和1,1-二氯乙烷迁移量的测定。 |
英文摘要: |
The work aims to evaluate the migration risk of vinyl chloride, vinylidene chloride and 1,1-dichloroethane from food contact recycled polyvinyl chloride materials. A gas chromatography method was developed to determine the migration of vinyl chloride, vinylidene chloride and 1,1-dichloroethane in food contact recycled polyvinyl chloride materials in water, acid, ethanol, olive oil and chemical alternative solvents. The three substances were separated on a DB-624 (60 m×250 μm×1.4 μm) capillary column, and detected with an electrical conductivity detector (ECD). Results showed that vinyl chloride, vinylidene chloride and 1,1-dichloroethane had good chromatographic separation effect and there were good linear relationships for the analytes in the range of 0.005-0.05 mg/kg, with a detection limit of 0.001 mg/kg and a quantitation limit of 0.005 mg/kg. When the addition amounts were 0.005 mg/kg, 0.01 mg/kg and 0.02 mg/kg, the recoveries ranged from 94.8% to 108%, with the relative standard deviations (n=6) of 0.0%-9.0% which was lower than 10%. With high accuracy and good precision, the established method could be used to determine the migration of vinyl chloride, vinylidene chloride and 1,1-dichloroethane in food contact recycled polyvinyl chloride materials. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|